RSE Chamber

RSE Chamber is a test site that can measure whether frequency components other than magnetic frequency or noise are excessively radiated. We design and construct chambers for Radiated Spurious conformance testing and certification testing of wireless products.

RSE Chamber
Performance and Specification
ItemStandard
Frequency Range 10kHz ~ 26GHz
Shield Effectiveness IEEE-STD-299 14kHz ~ 26GHz
T-VSWR EN 300 328(V1.8.1)
EN 301 893(V1.7.1)
  • Absorber : Guaranteed performance from 30 MHz to 26 GHz
  • Absorber Reflectivity Condition
    • 30MHz ~ 80MHz : -10dB
    • 80MHz ~ 300MHz : -20dB
    • 300MHz ~ above : -30dB
Chamber Size Customer's requirements