Products

Various field experiences and systematic construction
Precision machining and manufacturing according
to electromagnetic wave characteristics

Anechoic Chamber

Compact Chamber

Chamber for preliminary testing necessary for product development, such as debugging and countermeasures for the cause analysis of EMC issues in products. Compared to the regular chamber, the size of the chamber and the test auxiliary device are small, so the construction cost is low. Therefore, it is possible to reduce the time and cost of product certification by constructing a compact chamber.

Compact Chamber
Performance and Specification
ItemStandard
Frequency Range 30㎒ ~ 1㎓(Standard)
30㎒ ~ 18㎓(Extended)
RE Test(Pre-scan), RS Test, Trouble Shooting
Shield Effectiveness IEEE-STD-299 14kHz ~ 18GHz
Site Attenuation CISPR 16-1-4
ANSI 63.4
NSA (30MHz ~ 1GHz)
S-VSWR (1GHz ~ 18GHz)
Field Uniformity IEC 61000-4-3
EN 61000-4-3
80MHz ~ 18GHz
Uniformity Area 1.5mx1.5m at 3m Distance
Chamber Size Customer's requirements
Optimal laboratory space design and construction proposal to ensure chamber performance through simulation
Test Volume Customer's requirements
Measurement distance 3m
Performance Shield Effectiveness : 60dB at 14kHz, 100dB at 200kHz~18GHz
NSA : ≤±4.0dB (HOR & VER)
S-VSWR : ≤6.0dB (HOR & VER)
Field Uniformity : 0 to +6dB / 75%