Products
Various field experiences and systematic construction
Precision machining and manufacturing according
to electromagnetic wave characteristics
Anechoic Chamber
Compact Chamber
Chamber for preliminary testing necessary for product development, such as debugging and countermeasures for the cause analysis of EMC issues in products. Compared to the regular chamber, the size of the chamber and the test auxiliary device are small, so the construction cost is low. Therefore, it is possible to reduce the time and cost of product certification by constructing a compact chamber.
Performance and Specification
Item | Standard | |
---|---|---|
Frequency Range | 30㎒ ~ 1㎓(Standard) 30㎒ ~ 18㎓(Extended) |
RE Test(Pre-scan), RS Test, Trouble Shooting |
Shield Effectiveness | IEEE-STD-299 | 14kHz ~ 18GHz |
Site Attenuation | CISPR 16-1-4 ANSI 63.4 |
NSA (30MHz ~ 1GHz) |
S-VSWR (1GHz ~ 18GHz) | ||
Field Uniformity | IEC 61000-4-3 EN 61000-4-3 |
80MHz ~ 18GHz |
Uniformity Area | 1.5mx1.5m at 3m Distance | |
Chamber Size |
Customer's requirements Optimal laboratory space design and construction proposal to ensure chamber performance through simulation |
|
Test Volume | Customer's requirements | |
Measurement distance | 3m | |
Performance | Shield Effectiveness : 60dB at 14kHz, 100dB at 200kHz~18GHz | |
NSA : ≤±4.0dB (HOR & VER) | ||
S-VSWR : ≤6.0dB (HOR & VER) | ||
Field Uniformity : 0 to +6dB / 75% |