Products

Various field experiences and systematic construction
Precision machining and manufacturing according
to electromagnetic wave characteristics

Anechoic Chamber

RS Chamber

RS (Radiated Susceptibility/Immunity) test chamber for immunity test against radiated electromagnetic waves propagated in an external electromagnetic environment. By exclusively solving the high-demand RS test, it is possible to increase the operation rate of the regular chamber.

RS Chamber
Performance and Specification
ItemStandard
Frequency Range 80㎒ ~ 18㎓
Shield Effectiveness IEEE-STD-299 14kHz ~ 18GHz
Field Uniformity IEC 61000-4-3 80MHz ~ 18GHz
Chamber Size Customer's requirements
Test Volume Customer's requirements
Measurement distance 3m
Performance 0 to +6dB / 75%